Commercial Fire Sprinkler Systems2025-12-08T13:24:53+00:00

FIRE SPRINKLER SYSTEMS

Commercial Fire Sprinkler Systems

The British standards associated with sprinkler systems are as follows.

BS 9251 is the main British Standard covering fire sprinklers in this country. BS 9251 gives guidance for the design, installation, components, water supplies and backflow protection, commissioning, maintenance and testing of fire sprinkler systems installed for life safety purposes with additional benefits for property protection in residential and domestic occupancies.

Sprinkler systems are the most effective way to ensure that fires are suppressed or even extinguished before the fire rescue service can attend the site. Sprinkler systems save lives and can reduce injuries, the additional benefit of protecting firefighters who attend incidents and contribute to reducing the amount of damage to both property and the environment from fire. BS 9251: 2014, British Standard for Fire sprinkler Systems for Domestic and Residential Occupancies. Specifically for domestic and residential fire sprinkler installations. This standard sets the minimum requirements for the design, installation, and commission of a fire sprinkler system.

Specific requirements for a sprinkler systems are shown below:

  • Minimum flow rates: 60 litres per minute (lpm) through a single nozzle or 42lpm for multiple nozzles.
  • Minimum design: 2 nozzles for domestic and 4 nozzles for residential properties.
  • Minimum duration: 10 minutes for domestic properties, 30 minutes for residential properties.
  • Minimum nozzle spacings: no more than 2m from any wall or corner, no closer apart than 4m.

The National Fire Sprinkler Network Report 2017 stated the following, reducing average property loss by up to 70% . In the UK there has never been a fire death in a building with a fully maintained sprinkler system. Fires are extinguished or controlled in 99% of sprinkler protected properties.

Weekly Testing & Servicing of Fire Sprinkler Systems

  • Testing alarms, Pump/engine test.
  • Test air compressors if installed, Check isolating valve positions, Heating systems/frost protection Monthly: Battery level checks, Water Storage tank security

Routine Servicing of Fire Sprinkler Systems

  • Quarterly: Review of hazard, Inspection of pipework/supports, Water supply flow tests, Exercise stop valves, Test flow switches.
  • Six Monthly: Alternate pipe system – change over from air to water/ water to air, Check electrical signal to Fire brigade Annually: Pump service, Check tank ball float valves, Engine service, Valve service/inspection.
  • 3 Yearly: Inspect tanks, All valves & non return valves, Inspection, service and overhaul as necessary.
  • Other Intervals: Tank drain down & clean – 10 yearly, Sprinkler head performance testing to suit rules.

In the UK residential and domestic fire sprinklers need to be serviced at least every 12 months. This is a legal requirement, so you do need to ensure that you get these systems serviced if they’re in your premises and it’s your responsibility to do so. The legal requirement is set out by the British Standard BS 9251:2014 which covers the regulations for all types of fire sprinkler systems.

Enquiry

Huge Financial Implications From Skip Hire Site Fire

By |February 12th, 2024|Categories: News|Tags: , , , , |

Demolition costs for Lancaster fire may rise to £900k for Lancaster City Council who are grappling with a financial quandary in the aftermath of a massive fire at a former skip hire site. The potential demolition costs, estimated at £900,000, have prompted the council to consider various options to address the consequences of the fire that consumed a significant amount of waste.

New Draft Of BS 4422 Released For Public Comment: Your chance To Shape Fire Safety Standards

By |February 6th, 2024|Categories: News|Tags: , , , , , , |

The draft for public comment on BS 4422, addressing fire safety in the built environment, has been released by the British Standards Institute (BSI). Emphasising fire safety engineering and testing, the draft is open for feedback until March 5th.

The Five Key Steps Of Fire Risk Assessment

By |January 29th, 2024|Categories: News|Tags: , , , , , |

Fire safety in your business premises - Under the current Fire Safety Legislation, as the Responsible Person within your business, it is imperative to conduct a thorough and appropriate Fire Risk Assessment. This assessment aims to evaluate the risk of fire to your employees and others associated with your business and its operations.

Externally Monitored to Ensure that we meet a High Standard of Service.

As members of the SSAIB (Security Systems and Alarms Inspection Board), We maintain service records and monitor our success. The SSAIB, is a leading certification body for organisations providing security systems and services, fire detection alarm systems, and monitoring services. So, you can be confident that we strive to provide our clients with a reliable and professional level of service.