Aspirating Smoke Detection (ASD) systems represent some of the most advanced fire-detection technology available today.
Instead of relying on smoke to drift toward a fixed sensor, ASD systems continuously draw in air samples, allowing them to identify smoke at the earliest possible stage.
An aspiration detection system is a highly sensitive form of fire detection that can detect a fire at an early stage. The system takes samples of the air and tests them for the presence of smoke. The air is drawn by a pump from the various test points. A VESDA system actively draws air into its sampling holes which increases the chance of smoke being detected. Passive smoke detectors rely on smoke reaching them via diffusion or using the thermal energy of the fire.
There are multiple reasons for considering an ASD system. The detection sensitivity of such systems is frequently tailored to the particular application, to achieve the performance capability desired without being susceptible to unwanted alarms.
- Class of the detector (as defined in EN 54-20).
- Type or method of sampling (eg primary or secondary sampling).
- Compliance route (either prescriptive or performance based).
- Prime motivators for using an ASD system.
Primary sampling is arranged to sample from specific locations in the protected area where smoke is most likely to travel/accumulate. Secondary sampling is arranged such that the air sampling points are sited and spaced as an alternative to point type smoke detectors. Maintenance requirements should be considered during system design. In particular, the recommended maintenance period and techniques should be defined.
If performance parameters (such as air flow and transport time) are used to confirm system performance during maintenance, appropriate deviation limits should be defined. Typical examples might be: Airflow reading during maintenance should be confirmed as ± 20% of the values measured at commissioning. Measurements of transport time from the furthest hole (or dedicated maintenance test point) during maintenance should be confirmed to be within + 15% or + 3 seconds, whichever is the greater, of the same measurement taken at commissioning.
How Aspirating Smoke Detection Systems work
- A central detection unit uses a fan to actively draw air through a network of pipes that are installed throughout the area being monitored.
- The air is passed through a series of filters to remove contaminants and then sent to a detection chamber.
- Within the chamber, highly sensitive detection elements analyse the air for the presence of microscopic smoke particles.
- Sophisticated algorithms and dual-wavelength technology are used to differentiate between true smoke and other particulates, which helps to prevent false alarms.
- When smoke particles are detected, the system triggers an alarm, often at a much earlier stage than conventional detectors.
Key benefits of Aspirating Smoke Detection Systems
- Ultra-early warning: It can detect fires at the very earliest stage, often before smoke is visible.
- High sensitivity: ASDs can be up to 100 or even 2,000 times more sensitive than standard point-type detectors.
- Reliability: It is effective in challenging environments like cold rooms, dusty areas, high-ceilinged spaces, and data centers where air currents can make traditional detectors less effective.
- Centralised maintenance: The system is maintained and serviced from a single, central location.
- Enhanced safety: By providing a rapid and reliable early warning, it allows for faster intervention, which can prevent significant damage, business disruption, or loss of life.
BS 9991 Updated Being A Vital Advancement in Fire Safety Standards
The latest revision of BS 9991, the UK's essential fire safety standard for residential buildings, represents a significant milestone in enhancing fire safety practices. As fire safety concerns evolve, BS 9991:2024 introduces critical updates to address modern challenges and ensure improved safety in the design, management, and use of residential properties.
Happy New Year From SS Systems
As we welcome 2025, we want to take a moment to thank you for your continued support and custom. You are the heart of everything we do, and we are so grateful to have you as part of our journey.
2024 Season’s Greetings From SS Systems
Season’s greetings from all of us and we wish you a Merry Christmas and a Happy New Year. Thank you for your continued support this year, wishing you, your colleagues and families a very Merry Christmas from all at SS Systems. Please note that our office will be closed from 3pm on Tuesday 24th December 2024, re-opening at 9am on Thursday 2nd January 2025. Calls to 03300 417 170 during the period of closure will be directed to our on duty engineering team.
Externally Monitored to Ensure that we meet a High Standard of Service.
As members of the SSAIB (Security Systems and Alarms Inspection Board), We maintain service records and monitor our success. The SSAIB, is a leading certification body for organisations providing security systems and services, fire detection alarm systems, and monitoring services. So, you can be confident that we strive to provide our clients with a reliable and professional level of service.