Within England and Wales all fire curtains must be compliant to the Regulatory Reform (Fire Safety) Order 2005 (in Scotland the equivalent is: Fire (Scotland) Act 2005, Fire Safety (Scotland) Regulations 2006. This states that fire doors must be serviced every six (6) months to ensure they are in working condition and is mandatory. The servicing is to ensure suitability and safety in the event of an accident. The smoke curtain doesn’t descend to ground level i.e., ceiling to floor and is usually set above head height to prevent interference with the means of escape.

However, a fire curtain is usually installed to provide fire separation between two spaces like a mechanical door. Regulation 5 of the Workplace (Health Safety and Welfare) Regulations 1992 states that all powered doors must be inspected at regular intervals for testing, adjustment, lubrication, suitability and any repair or cleaning is undertaken. The owner of property must comply with certain laws to prevent the spread of smoke and flames. The Regulatory Reform (Fire Safety) Order 2005 states all emergency doors must be regularly serviced and that the responsible person must ensure that the premises and any facilities, equipment and devices provided are subject to a suitable system of maintenance and are maintained in an efficient state and in efficient working order and in good repair.

We recommend that you undertake a risk assessment to identify and remove all fire risks where possible which would include existing fire curtains, smoke curtains and any other passive fire prevention equipment and if these items are required. Please contact us to arrange your FRA, Fire curtain and or smoke curtain service inspections.

When Would You Need Fire Curtains?
You would need fire curtains in the following situations:

  1. Open-plan layouts
    1. Where open spaces exist without compartmentalisation (e.g., shopping centres, lobbies, atria).
    2. Fire curtains act as temporary fire-rated barriers to maintain fire compartmentation.
  2. Protected means of escape
    1. Where escape routes (e.g., corridors or stairwells) need to be protected from fire/smoke.
    2. Fire curtains help ensure safe evacuation and prevent smoke ingress.
  3. Replacing fire doors or shutters
    1. In cases where traditional fire doors or shutters are impractical, like for architectural or accessibility reasons.
  4. To comply with Building Regulations
    1. Required by Approved Document B (Fire Safety) when fire compartmentation or protected routes are necessary.
  5. In heritage buildings
    1. Where installing permanent barriers (walls or doors) would affect the building’s historical integrity.
  6. Smoke control systems
    1. Some curtains are specifically designed as smoke curtains, used to channel or contain smoke during a fire.

Relevant British Standard for Fire Curtains
The primary standard is BS 8524-1:2013 Active fire curtain assemblies – Part 1: Specification

This standard covers:

  • Design
  • Performance
  • Installation
  • Testing of active fire curtain barrier assemblies

Also relevant:

  • BS 8524-2:2013 – Code of practice for application, installation, and maintenance
  • BS EN 1634-1 – Fire resistance and smoke control tests for door and shutter assemblies
  • BS EN 12101-1 – For smoke curtains, under smoke and heat control systems

Maintenance Requirements
Under BS 8524-2:2013, and aligned with general fire safety obligations under the Regulatory Reform (Fire Safety) Order 2005, maintenance is critical.

  • Minimum maintenance frequency
    • At least once every 6 months by a competent person
  • Additional checks:
    • Weekly or monthly visual inspections (can be done by on-site facilities staff)
    • Functional test to ensure the curtain deploys correctly (often integrated with fire alarm tests)
  • What should be checked:
    • Curtain descent speed and alignment
    • Side guides and rollers
    • Fabric integrity
    • Motor function and battery backup
    • Control system (signal from fire alarm)

Fire Curtain Summary

  • When Needed Open-plan spaces, escape routes, replacing fire doors, smoke control
  • Main British Standard BS 8524-1:2013 & BS 8524-2:2013
  • Maintenance Frequency Every 6 months (minimum) by a competent person
  • Additional Checks Weekly/monthly visual & functional checks by facilities/maintenance teams

Enquiry

Updated Guidance On Scope Of Services For Fire Risk Assessors

By |September 8th, 2025|Categories: News|Tags: , , , , |

The Fire Industry Association (FIA) has published Version 2 of its Fire Risk Assessors "Standard Scope of Services", setting out clearer expectations for the fire risk assessment process. This long-awaited update provides stronger legislative alignment, improved transparency, and a shared understanding for both assessors and their clients.

Tough New Laws To Make Online Marketplaces Reduce The Risk Of Fire

By |September 1st, 2025|Categories: News|Tags: , , , , |

The UK Government has taken a major step toward making online shopping safer with the Product Regulation and Metrology Act, which has now received Royal Assent. As part of the broader Plan for Change, the new legislation strengthens consumer protection by holding online marketplaces to the same safety standards as traditional high street retailers.

Battery Energy Storage Systems & The Impact On Fire Safety Challenges

By |August 26th, 2025|Categories: News|Tags: , , , , |

As Battery Energy Storage Systems (BESS) become central to the transition to reduced emissions in the UK, a critical question emerges. Are firefighting strategies keeping pace with the rapid rise of this technology? While BESS supports renewable energy integration and strengthens grid resilience, it also introduces new, serious hazards particularly for first responders, people and property.

Externally Monitored to Ensure that we meet a High Standard of Service.

As members of the SSAIB (Security Systems and Alarms Inspection Board), We maintain service records and monitor our success. The SSAIB, is a leading certification body for organisations providing security systems and services, fire detection alarm systems, and monitoring services. So, you can be confident that we strive to provide our clients with a reliable and professional level of service.

Go to Top