Portable Appliance Testing (PAT) Testing
Commercial Portable Appliance Testing (PAT) Testing
When a PAT test (Portable Appliance Testing) is undertaken in the UK, it involves the examination and testing of electrical appliances to ensure they are safe to use.
When PAT test (Portable Appliance Testing) is undertaken in the UK, it involves the examination and testing of electrical appliances to ensure they are safe to use. This is part of a broader electrical safety regime, particularly in workplaces and rental properties.
What is included in a PAT Test?
PAT testing typically consists of three main stages:
1. Visual Inspection
A thorough visual check to spot obvious signs of damage or misuse:
- Damaged plugs or casings.
- Loose wires or exposed conductors.
- Signs of overheating (discolouration, melting).
- Cable condition (e.g., fraying, crushing).
- Correctly wired and fused plugs.
- Equipment suitability for environment (e.g. IP rating for wet areas).
2. Electrical Testing
This depends on the class of appliance (Class I, II, or III), but may include:
- Damaged plugs or casings.
- Loose wires or exposed conductors.
- Signs of overheating (discolouration, melting).
- Cable condition (e.g., fraying, crushing).
- Correctly wired and fused plugs.
- Equipment suitability for environment (e.g. IP rating for wet areas).
Some devices like Class II appliances (double insulated) won’t need an earth test.
3. Labelling & Documentation
- “Pass” or “Fail” label with date, tester ID, and retest date (optional).
- Log of test results (manual or digital).
- Certificate or report (for compliance records).
Standards that Govern PAT Testing in the UK
PAT testing in the UK is not specifically required by a single law but is covered under several Health & Safety regulations. Key standards and regulations include:
Key Legislation:
- Electricity at Work Regulations 1989 – Requires that electrical equipment is maintained in a safe condition.
- Health and Safety at Work Act 1974 – Employers must ensure the safety of employees and the public.
- Provision and Use of Work Equipment Regulations 1998 (PUWER) – Equipment must be suitable and safe for use.
- Management of Health and Safety at Work Regulations 1999 – Risk assessments must be carried out.
Standards and Guidance:
- IET Code of Practice for In-Service Inspection and Testing of Electrical Equipment – The main guidance document for PAT testing procedures in the UK (currently 5th Edition, published in 2020).
- BS EN 50699:2020 – “Recurrent Tests of Electrical Equipment” – Supports the IET Code of Practice, focusing on periodic testing.
- BS 7671 (IET Wiring Regulations) – Electrical installation regulations – While more focused on fixed wiring, some crossover with portable appliances exists.
Equipment Commonly PAT Tested
- Computers, monitors, printers.
- Kettles, microwaves, toasters.
- Extension leads.
- Power tools.
- Chargers and adaptors.
How Often Should PAT Testing Be Done?
There is no fixed legal interval, but frequency should be based on:
- Risk assessment.
- Type of equipment.
- Usage environment.
- Manufacturer’s recommendations.
Developer Fined £165,000 For Fire Safety Regulation Breaches During Warehouse To Apartments Conversion
A property developer has been fined £165,000 for repeated breaches of fire safety regulations during the conversion of a warehouse into residential flats—putting lives at risk and prompting enforcement action from authorities.
Fire Service Sees Five-Year High in Fire Incidents
Cambridgeshire Fire and Rescue Service (CFRS) has reported a sharp increase in fire-related incidents, reaching the highest levels seen in the past five years. In March alone, firefighters responded to more than 160 fires, a significant rise from 111 during the same month last year. April saw over 200 incidents, up from 131 in April 2024. Over the past 12 months, CFRS recorded 1,911 incidents countywide representing a 13% increase compared to the previous year.
Converted Church Blaze Leads To Prosecution & Major Fines
A devastating fire in a converted church in Preston, which had been repurposed to house students and residents, has resulted in significant legal repercussions due to severe fire safety breaches. The incident exposed major failings and has led to prosecutions and heavy financial penalties for those responsible.
Externally Monitored to Ensure that we meet a High Standard of Service.
As members of the SSAIB (Security Systems and Alarms Inspection Board), We maintain service records and monitor our success. The SSAIB, is a leading certification body for organisations providing security systems and services, fire detection alarm systems, and monitoring services. So, you can be confident that we strive to provide our clients with a reliable and professional level of service.