Commercial Portable Appliance Testing (PAT) Testing2025-11-28T12:02:56+00:00

Portable Appliance Testing (PAT) Testing

Commercial Portable Appliance Testing (PAT) Testing

When a PAT test (Portable Appliance Testing) is undertaken in the UK, it involves the examination and testing of electrical appliances to ensure they are safe to use.

When PAT test (Portable Appliance Testing) is undertaken in the UK, it involves the examination and testing of electrical appliances to ensure they are safe to use. This is part of a broader electrical safety regime, particularly in workplaces and rental properties.

What is included in a PAT Test?

PAT testing typically consists of three main stages:

1. Visual Inspection
A thorough visual check to spot obvious signs of damage or misuse:

  • Damaged plugs or casings.
  • Loose wires or exposed conductors.
  • Signs of overheating (discolouration, melting).
  • Cable condition (e.g., fraying, crushing).
  • Correctly wired and fused plugs.
  • Equipment suitability for environment (e.g. IP rating for wet areas).

2. Electrical Testing
This depends on the class of appliance (Class I, II, or III), but may include:

  • Damaged plugs or casings.
  • Loose wires or exposed conductors.
  • Signs of overheating (discolouration, melting).
  • Cable condition (e.g., fraying, crushing).
  • Correctly wired and fused plugs.
  • Equipment suitability for environment (e.g. IP rating for wet areas).

Some devices like Class II appliances (double insulated) won’t need an earth test.

3. Labelling & Documentation

  • “Pass” or “Fail” label with date, tester ID, and retest date (optional).
  • Log of test results (manual or digital).
  • Certificate or report (for compliance records).

Standards that Govern PAT Testing in the UK

PAT testing in the UK is not specifically required by a single law but is covered under several Health & Safety regulations. Key standards and regulations include:

Key Legislation:

  • Electricity at Work Regulations 1989 – Requires that electrical equipment is maintained in a safe condition.
  • Health and Safety at Work Act 1974 – Employers must ensure the safety of employees and the public.
  • Provision and Use of Work Equipment Regulations 1998 (PUWER) – Equipment must be suitable and safe for use.
  • Management of Health and Safety at Work Regulations 1999 – Risk assessments must be carried out.

Standards and Guidance:

  • IET Code of Practice for In-Service Inspection and Testing of Electrical Equipment – The main guidance document for PAT testing procedures in the UK (currently 5th Edition, published in 2020).
  • BS EN 50699:2020 – “Recurrent Tests of Electrical Equipment” – Supports the IET Code of Practice, focusing on periodic testing.
  • BS 7671 (IET Wiring Regulations) – Electrical installation regulations – While more focused on fixed wiring, some crossover with portable appliances exists.

Equipment Commonly PAT Tested

  • Computers, monitors, printers.
  • Kettles, microwaves, toasters.
  • Extension leads.
  • Power tools.
  • Chargers and adaptors.

How Often Should PAT Testing Be Done?

There is no fixed legal interval, but frequency should be based on:

  • Risk assessment.
  • Type of equipment.
  • Usage environment.
  • Manufacturer’s recommendations.

Enquiry

Alarm Signalling Connectivity & Guidance

By |June 24th, 2024|Categories: News|Tags: , , , , , |

In Spring 2024, BT announced that it will withdraw Redcare operations on August 1, 2025. This unexpected decision has significant implications for the commercial alarm industry. While monitoring operations will continue for the next 18 months, existing customers should understand the importance of this announcement.

Navigating Fire Safety For Historical Buildings

By |June 17th, 2024|Categories: News|Tags: , , , , , |

Navigating fire safety for historic sites involves unique challenges and scenarios that may not apply to modern buildings and structures. Heritage buildings, often constructed long before modern fire safety regulations existed, present unique challenges due to their use of materials now considered outdated and vulnerable to fire.

Construction Site Fire Safety Under The Spotlight

By |June 10th, 2024|Categories: News|Tags: , , , , , |

Seven people were hospitalised following a construction site fire in Canning Town, Newham, on June 4, 2024. The London Fire Brigade (LFB) received approximately 30 calls about the fire, which started shortly after 8 am. Ten fire engines and 70 firefighters from Plaistow, Poplar, East Ham, and nearby stations responded to the scene, where they found a ground-floor commercial unit of a 10-storey building under construction engulfed in flames.

Externally Monitored to Ensure that we meet a High Standard of Service.

As members of the SSAIB (Security Systems and Alarms Inspection Board), We maintain service records and monitor our success. The SSAIB, is a leading certification body for organisations providing security systems and services, fire detection alarm systems, and monitoring services. So, you can be confident that we strive to provide our clients with a reliable and professional level of service.

Go to Top